A seven-core SiHF heat resistant silicone rubber cable, sold by the metre and cut to your chosen length. SiHF is used wherever cable insulation is exposed to high temperature fluctuations, which makes it well suited to sauna connections; the elastic core insulation also allows it to serve as a flexible connecting cable. It carries a red/brown rubber sheath and is rated from -60°C to +180°C, with brief peaks to +220°C. Choose between 1.5 mm² and 2.5 mm² core sizes from the dropdown, and note that the cable must be installed by a skilled electrician in accordance with all relevant regulations.

Features

  • Sold per metre: Cut to size, so you order exactly the length your installation needs.
  • Two core sizes: Choose 7-core 1.5 mm² or 2.5 mm² from the dropdown.
  • High heat tolerance: Rated from -60°C to +180°C, with brief peaks to +220°C.
  • Built for saunas: Suitable for sauna connections where insulation faces high temperature fluctuations.
  • Flexible in use: The elastic core insulation allows it to work as a flexible connecting cable.
  • Certified construction: Manufactured in accordance with DIN VDE 0250-1 and DIN VDE 0285-525-2-83 / DIN EN 50525-2-83.
  • Professional installation: Must be installed by a skilled electrician in accordance with all relevant regulations.

Technical Specification
Specifications
TypeSiHF special silicone hose cable with increased heat resistance
Cores7
Conductor cross-section1.5 mm² or 2.5 mm² (select in the dropdown)
SheathRed/brown rubber
Sold asPer metre, cut to size; all lengths available
StandardsDIN VDE 0250-1 and DIN VDE 0285-525-2-83 / DIN EN 50525-2-83
Temperature range-60°C to +180°C (briefly +220°C)
Weather resistanceExcellent; usable at both high and low temperatures down to -60°C
Limit temperature on the conductor, in operation+180°C
Nominal voltage U0/U300/500 V
Test voltage2000 V
Breakdown voltageMin. 5000 V
Insulation resistanceMin. 200 MOhm x km
Radiation resistanceUp to 20x106 cJ/kg (up to 20 Mrad)
Minimum bending radiusMoving 7.5x cable Ø; not moving 4x cable Ø
Current carrying capacity
Up to +145°C ambient temperatureIn accordance with DIN VDE 0100
+150°C ambient temperatureLoad capacity 100%
+155°C ambient temperatureLoad capacity 91%
+160°C ambient temperatureLoad capacity 82%
+165°C ambient temperatureLoad capacity 71%
+170°C ambient temperatureLoad capacity 58%
+175°C ambient temperatureLoad capacity 41%

Safety

Must be used in accordance with all relevant regulations and installed by a skilled electrician.

Ordering

Select the correct core size in the dropdown and order the number of metres your run requires; the cable is cut to size. If you are unsure which size suits your heater, contact support@finnmarksauna.com with your heater model before ordering.

Downloads
Delivery & Returns

Delivery

We offer fast and reliable delivery to customers across the UK and beyond. For full details on shipping times and costs, please review our delivery policy.

Returns

We offer hassle-free returns within 30 days of purchase, so you can shop with complete confidence. For details, see our returns policy.

Warranty & Quality Promise

We are committed to delivering products of the highest quality, for details surrounding warranty please contact us.

Related Products